* Stifle progress output in build.psm1 for some operations
Modify test failure presentation to use platform available XML methods
* Add timeout support for returning runtime parsing errors
Some of the language/parser tests have been hanging in a non-reproducable manner which
causes the CI system to invalidate the entire run. This change adds support for timeout
which will fail a test if it runs to long, rather than invalidate the entire run.
current behavior is still supported, and is not done in a new session:
PS> get-runtimeerror -src '1/'
At line:1 char:3
+ 1/
+ ~
You must provide a value expression following the '/' operator.
+ CategoryInfo : ParserError: (:) [], ParentContainsErrorRecordException
+ FullyQualifiedErrorId : ExpectedValueExpression
Adding a timeout will do the operation in a async powershell session
PS> get-runtimeerror -src '1/' -timeout 5
You must provide a value expression following the '/' operator.
+ CategoryInfo : ParserError: (:) [], ParentContainsErrorRecordException
+ FullyQualifiedErrorId : ExpectedValueExpression
If the operation takes longer than the supplied timeout, a timeout error will be returned
PS> get-runtimeerror -src 'start-sleep 6' -timeout 2
get-runtimeerror : Operation Timed Out ('start-sleep 6')
At line:1 char:1
+ get-runtimeerror -src 'start-sleep 6' -timeout 2
+ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+ CategoryInfo : NotSpecified: (:) [Write-Error], WriteErrorException
+ FullyQualifiedErrorId : Microsoft.PowerShell.Commands.WriteErrorException,Get-RuntimeError
* Modify native linux command tests to skip on Windows and pending on Mac
* remove verbose and progress output from help tests
* Be sure that Feature Counter tests only run on Windows
Also, only call add-type in CounterTestHelperFunctions.ps1 if we're going to actually run the tests
* do not run any get-computerinfo tests on non-windows systems
* suppress progress output from PowerShell Get tests
* remove -quiet from API and CRON Builds
Travis watches output from the build to ensure that it hasn't hung
we need to find a balance between too much output and not enough output.
A run which has too much output is killed because it looks like an error loop
A run which has too little output is killed because it looks like a hang
* Remove commented line in Import-Counter.Tests.ps1
Remove extraneous extra line in PowerShellGet.Tests.ps1
* Change `-as "type"` to `-as [type]` in build.psm1
Alter timeout to 10 seconds to be improve chances of not timing out for runtime parser checks
improve logic for counter tests to also skip for IoT
* use the existing function of SkipCounterTests rather than duplicate the logic in import-counter.tests.ps1
* All test reported as skipped if not applicable to the platform
Fixed files:
powershell\Modules\Microsoft.PowerShell.Management\Clear-EventLog.Tests.ps1:1:if
($IsWindows -and !$IsCoreCLR) {
powershell\Modules\Microsoft.PowerShell.Management\Get-ComputerInfo.Tests.ps1:1325:
return
powershell\Modules\Microsoft.PowerShell.Management\Get-EventLog.Tests.ps1:1:if
($IsWindows -and !$IsCoreCLR) {
powershell\Modules\Microsoft.PowerShell.Management\New-EventLog.Tests.ps1:1:if
($IsWindows -and !$IsCoreCLR) {
powershell\Modules\Microsoft.PowerShell.Management\Registry.Tests.ps1:7:
if ($IsWindows -eq $false) {
powershell\Modules\Microsoft.PowerShell.Management\Registry.Tests.ps1:167:
if ($IsWindows -eq $false) {
powershell\Modules\Microsoft.PowerShell.Management\Remove-EventLog.Tests.ps1:1:if
($IsWindows -and !$IsCoreCLR) {
powershell\Modules\Microsoft.PowerShell.Management\TimeZone.Tests.ps1:17:if
($IsWindows) {
powershell\Modules\Microsoft.PowerShell.Security\FileCatalog.Tests.ps1:6:if
($IsWindows) {
powershell\engine\Help\HelpSystem.Tests.ps1:112: if ($IsWindows)
* Fix test after code review
* Move skiping to common 'try'
A non-terminating error is thrown when the namespace does not exist by
Get-CimInstance. The namespace is not present on OS versions below Windows
10. It is not caught in the try-catch unless ErrorAction Stop is added.
Resolving #2570.
Ignore drive paths in the check. If the input is a drive path,
then "\" is passed as the path to GetDriveQualifiedPath with drive info.
Since, the path here starts with "\", treatAsRelative is set to false
which prevents further formatting of this path.
The check is only valid for PSDrives with root path equals to UNC paths or the paths
in unix.
Resolving #2206
Set-Content fails to create a file for PSDrive path, if the path root
begins with defaultPathSeperatorString (ex: UNC path and paths in Single
rooted filesystems like Unix)
These are not currently implemented and so should not show up as
available.
The *-Computer cmdlets are already not compiled for Unix (and so not
available), so let's not declare them in the manifest.
The Get-ComputerInfo cmdlet does not work on Unix and so should not be
made available.
Test-Connection depends on an unavailable WMI provider.
Get/Set-TimeZone are not yet ported.