1.5 KiB
Remill Intrinsics
Remill models the semantics of instruction logic and its effects on processor and memory state, but it does not model memory access behaviors or certain types of control flow. Remill defers the "implementation" of those to the consumers of the produced bitcode. Deferral is performed using Remill intrinsics, declared in Intrinsics.h and defined in Intrinsics.cpp.
In Remill's implementation of an instruction, memory operands are represented by their addresses, but accessed only via intrinsics. For example, the __remill_read_memory_8 intrinsic function represents the action of reading 8 bits of memory. Via this and similar intrinsics, downstream tools can distinguish LLVM load and store instructions from accesses to the modeled program's memory. Downstream tools can, of course, implement memory intrinsics using LLVM's own memory access instructions.
The typical developer working on extending Remill does not need to work with Remill's memory access intrinsics directly, because they are actually wrapped by Remill's operators. Refer to the Operators documentation for more information on those.