- Implement complete cross-process injection engine via snd_inj_ctx_t - Track explicit remote_entry_point for safe thread hijacking and PE execution - Refactor standalone syscall resolvers into a unified pipeline (scan/sort) - Perfect status code system by purging generic fallbacks in favor of highly-specific, domain-aware error codes - Fix minor pointer validation and parsing bugs in the reflective loader
7.3 KiB
Loaders: Techniques
The loaders domain maps PE images into memory and prepares them for execution without the Windows loader. The first implemented technique is Reflective PE Loading under loaders/reflective/.
Prerequisite reading: PE parser techniques, Dependency Injection
Reflective PE Loading
Reflective loading maps and executes a PE (EXE or DLL) entirely in the local process without LoadLibrary. The image does not appear in the PEB module lists — no loader telemetry from standard module enumeration.
Original research: Reflective DLL Injection by Stephen Fewer (2008)
Context and DI
Operations run through snd_ldr_pe_ctx_t with injected primitives:
snd_ldr_pe_ctx_t ctx = {0};
ctx.raw_source = &payload_buf;
ctx.mem_api = &snd_mem_sys; // or snd_mem_win, snd_mem_nt
ctx.mod_api = &snd_mod_nt; // or snd_mod_win
Every memory and import operation calls ctx->mem_api / ctx->mod_api — never hardcoded Win32 APIs.
Target block (snd_pe_target_t)
| Field | Role |
|---|---|
local_base |
Locally allocated image mapping (RW during fixups) |
execution_base |
Base used for relocation delta (defaults to local_base; set to remote base for injection bake) |
delta_offset |
execution_base - ImageBase |
entry_point |
Resolved entry (after snd_ldr_pe_get_entry_point) |
allocated_size |
SizeOfImage |
When local_base != execution_base, the image was prepared for a remote address (Classic PE injection). Local execute/detach paths refuse to run.
Stage Machine (snd_ldr_pe_stage_t)
| Stage | Set by | Meaning |
|---|---|---|
SND_STAGE_UNINITIALIZED |
— | Empty context |
SND_STAGE_PARSED |
snd_pe_parse in chain/prepare |
Raw PE validated |
SND_STAGE_MEM_ALLOCATED |
snd_ldr_pe_allocate_and_copy_image |
Virtual memory reserved |
SND_STAGE_SECTIONS_MAPPED |
same (after section copy + re-parse mapped) | Sections copied, parser re-run with is_mapped=TRUE |
SND_STAGE_RELOCATED |
snd_ldr_pe_apply_relocations |
Base relocations applied |
SND_STAGE_IMPORTS_RESOLVED |
snd_ldr_pe_resolve_imports |
IAT patched |
SND_STAGE_READY_FOR_EXECUTION |
snd_ldr_pe_apply_memory_protections |
Per-page protections applied |
SND_STAGE_EXECUTED |
snd_ldr_pe_execute_image |
Entry point invoked |
Engine functions validate stage ordering and return SND_STATUS_INVALID_STAGE_SEQUENCE on violation.
Reflective Pipeline (local execution)
1. Parse (SND_STAGE_PARSED)
snd_pe_parse(raw_source, FALSE, &ctx.pe) — raw file layout. Validates DOS/NT signatures and optional header magic.
2. Architecture check
snd_ldr_pe_compatibility_check — rejects cross-bitness payloads before allocation.
3. Allocate and copy (SND_STAGE_MEM_ALLOCATED → SND_STAGE_SECTIONS_MAPPED)
snd_ldr_pe_allocate_and_copy_image:
- Tries
mem_api->allocat preferredImageBase, falls back to OS-chosen base. - Copies headers and each section from file offsets to virtual addresses; zero-fills bss.
- Re-parses the mapped buffer with
is_mapped=TRUEso subsequent RVA lookups use virtual layout.
4. Apply relocations (SND_STAGE_RELOCATED)
snd_ldr_pe_apply_relocations sets delta_offset = execution_base - ImageBase and calls snd_pe_apply_relocations. No-op when delta is zero.
5. Resolve imports (SND_STAGE_IMPORTS_RESOLVED)
snd_ldr_pe_resolve_imports → snd_pe_resolve_imports(local_base, mod_api, &pe). Requires mapped parser context.
6. Apply protections (SND_STAGE_READY_FOR_EXECUTION)
snd_ldr_pe_apply_memory_protections walks the image page-by-page, merging section characteristics per page, and applies protection runs via mem_api->protect. Headers default to read-only; section flags drive execute/read/write combinations. Avoids blanket PAGE_EXECUTE_READWRITE unless section flags demand it.
7. Execute (SND_STAGE_EXECUTED)
snd_ldr_pe_execute_image:
snd_ldr_pe_get_entry_pointsnd_ldr_pe_execute_tls_callbacks(DLL_PROCESS_ATTACH)- DLL: call
DllMain(hinst, DLL_PROCESS_ATTACH, NULL)— failure returnsSND_STATUS_DLL_INITIALIZATION_FAILED - EXE: jump to entry point (does not return)
TLS and entry execution require local_base == execution_base.
8. Detach (optional cleanup)
snd_ldr_pe_detach_image — only when stage == EXECUTED and bases match locally:
- DLL:
DllMain(DETACH), TLS detach callbacks snd_ldr_pe_free_mapped_image— releases virtual memory, re-parses raw source
Chain vs. Manual Staging
Full chain — snd_ldr_pe_prepare_image runs parse → compat → alloc/copy → reloc → imports → protections (no TLS, no entry).
Execute — snd_ldr_pe_execute_image runs TLS + entry (local only).
Manual staging — call individual snd_ldr_pe_* engine functions to pause between stages (sleep obfuscation, custom instrumentation).
Post-load DLL exports (PoC pattern)
After snd_ldr_pe_execute_image, PoCs loader_winapi and loader_nowinapi optionally resolve a named export and invoke it through the FFI bridge:
FARPROC fn = NULL;
snd_ldr_pe_get_proc_address(&ctx, export_name, &fn);
UINT_PTR ret = snd_ffi_execute((PVOID)(UINT_PTR)fn, argc, argv);
This runs after DllMain(DLL_PROCESS_ATTACH) has already fired during execute. Requires ctx.stage >= SND_STAGE_READY_FOR_EXECUTION (execute advances to EXECUTED; get_proc_address accepts >= READY).
Required context fields
Before calling snd_ldr_pe_prepare_image:
| Field | Required |
|---|---|
raw_source |
Valid snd_buffer_t with PE bytes |
mem_api |
Non-NULL with alloc, free, protect |
mod_api |
Non-NULL with load_library, get_proc_address |
target.execution_base defaults to local_base inside allocate_and_copy_image when unset. Injection sets it to the remote base before relocations.
Integration with Classic PE Injection
snd_inj_classic_pe uses a subset of the loader engine with a different ordering:
| Loader step | Used in injection? | Notes |
|---|---|---|
| Parse + alloc/copy | Yes | Local RW image |
| Relocations | Yes | execution_base = remote_base before apply |
| Imports | Yes | Local IAT fixup |
| Per-section protections | No | Injection uses flat RX on remote region |
| TLS + local execute | No | Remote thread starts at entry RVA |
| Write + remote protect + thread | Injection domain | Via snd_inj_ctx_t |
See injection techniques.
KnownDlls (bootstrapping, not a loader)
Retrieving clean ntdll.dll from \KnownDlls for syscall bootstrap is documented under mapping primitives. It is a primitive concern, not a loader technique.
Typical sequence before snd_mem_sys / snd_proc_sys:
PVOID clean_ntdll = NULL;
snd_om_knowndll_map(&snd_map_nt, L"ntdll.dll", &clean_ntdll);
snd_syscall_set_ntdll(clean_ntdll);
snd_syscall_strategy_set(snd_syscall_resolve_ssn_scan);
snd_syscall_strategy_add(snd_syscall_resolve_ssn_sort);
Planned Loader Techniques